Viral & vector sheddingViral shedding studies for gene therapies, oncolytic viruses and mRNA products
Single Cell Discoveries develops, validates and runs qPCR and dPCR shedding assays for AAV, adenoviral and retroviral vectors, including lentiviral vectors, as well as oncolytic viruses. Studies run under GLP for preclinical work, under GCLP for clinical samples, or as non-GLP studies, in our laboratory in Gothenburg, Sweden.
We are ISO/IEC 17025 accredited.
Trusted By
Quality assurance & compliance
We are accredited for Good Laboratory Practice (GLP) by the Swedish Board for Accreditation and Conformity Assessment (SWEDAC) for qPCR, dPCR, and molecular biology.
Specifications
Shedding studies at a glance
A viral or vector shedding study measures whether a gene therapy vector, oncolytic virus, or nucleic acid product is released from a treated patient or animal, how much is released, and for how long. This includes testing samples such as urine, feces, saliva and nasopharyngeal fluids, as well as assessing potential shedding through the skin.
| Item | Details |
|---|---|
| Products | AAV and adenoviral vectors; lentiviral and retroviral vectors; oncolytic viruses; mRNA and other nucleic acid products |
| Analytes | Vector DNA, vector RNA |
| Sample matrices | Feces, urine, saliva, sputum, nasopharyngeal fluids, tears, skin lesions (pustules, sores, wounds), semen, vaginal secretions, breast milk, swabs |
| Species | Relevant animal species (GLP non-clinical) and human (clinical shedding) |
| Platforms | qPCR, RT-qPCR and dPCR; sequencing to check vector integrity |
| Quality framework | GLP (preclinical), GCLP (clinical) or non-GLP |
| Lowest quantifiable level | Assay and matrix- specific LOD / LLOQ expressed as copies/mL, copies/mg or copies/swab. |
| Sample volume | Matrix-specific; optimized to achieve the required analytical sensitivity |
| Deliverables | Qualification or validation report; sample results per volume or mass of sample. |
| Laboratory | Gothenburg, Sweden |
When do you need a shedding study?
Shedding, biodistribution and pharmacokinetics answer different questions, and regulators treat them separately. Biodistribution follows the product inside the body, in target and non-target tissues. Meanwhile, pharmacokinetics follows how much product is in the blood over time and how fast it is cleared. On the other hand, shedding follows what leaves the body.
When to pick another study
- You need to know where the product goes inside the body.
That is a biodistribution study, which measures vector genomes and transgene expression in tissues. Our Biodistribution page also covers single-cell and spatial biodistribution, which shows which cell types take up the vector and express the transgene, with custom enrichment for lowly expressed transcripts such as AAV transgenes. - You need exposure and persistence in blood over time.
That is a pharmacokinetic study. See Pharmacokinetics. - You need to show that shed material is infectious.
qPCR and dPCR measure nucleic acid and cannot tell intact, infectious particles from degraded fragments. Infectivity is tested in a cell-based assay, typically on PCR-positive samples.
When is a shedding study the right choice?
- Your product is a viral vector-based gene therapy or an oncolytic virus.
Regulators expect shedding data for these products, from preclinical studies through clinical trials. - You need to know what leaves the body, and for how long.
Shedding profiles over time in feces, urine, saliva or swabs feed into the environmental risk assessment and the precautions for close contacts and healthcare staff.
Assay design
Shedding assays by product type
Each shedding assay is designed for your construct and your drug product format. Primers and probes target sequences that do not occur naturally, such as vector-transgene junctions, promoter regions or codon-optimized transgene sequences, so the assay detects the therapeutic product and not endogenous genes or wild-type virus.
AAV and adenoviral vector shedding
We quantify AAV and adenoviral vector genomes in excreta and secreta by qPCR and dPCR across the full sampling schedule, so you can show when shedding starts, peaks and stops.
Lentiviral and retroviral vectors
For lentiviral and retroviral vectors, assays target vector-specific elements. Where the shed form is particle-associated RNA, the assay includes a reverse transcription step, controlled with RNA spike-ins. For replication-competent lentivirus or retrovirus testing, see RCL testing.
Oncolytic viruses
Oncolytic viruses replicate, so they can be shed for longer than non-replicating vectors. We design assays that separate the therapeutic virus from wild-type strains, for example by targeting an inserted transgene or a modified region of the viral genome.
Which samples can be analyzed for shedding?
Shedding matrices are among the hardest samples in molecular bioanalysis. Feces, urine and saliva contain organic matter, host proteins, endogenous DNA and microorganisms that can inhibit the PCR, while the analyte is often present at only a few copies.
| Sample group | Matrices |
|---|---|
| Excreta | Feces, urine |
| Secreta | Saliva, sputum, nasopharyngeal fluids, tears, semen, vaginal secretions, breast milk |
| Skin | Skin lesions such as pustules, sores or wounds |
| Blood | Blood (FDA guidance treats blood as part of pharmacokinetics rather than shedding; we analyze it under Pharmacokinetics) |
Uncommon matrices, such as skin swabs, semen or breast milk, start with a short feasibility test of extraction recovery and PCR inhibition before the assay is qualified.
qPCR or dPCR for shedding samples?
Quantitative PCR (qPCR) is the established method for shedding studies: the ICH considerations on virus and vector shedding recommend qPCR-based assays because they are sensitive, reproducible and rapid. Digital PCR (dPCR) adds two advantages that matter in shedding matrices: (1) it is less affected by PCR inhibitors, so samples need less dilution, and (2) it counts target molecules directly, without a standard curve.
| Criterion | qPCR | dPCR |
|---|---|---|
| Quantification | Against a standard curve | Direct counting of positive partitions, no standard curve |
| Tolerance to PCR inhibitors | Lower; inhibitory matrices often need dilution | Higher; minimal dilution needed |
| Typical sensitivity | Around 10 copies per reaction | As few as 1 to 2 copies per reaction |
| Dynamic range | Wide | Narrower at high concentrations |
| Typical use in shedding studies | Established workflows, wide concentration ranges, larger sample series | Low-copy targets in inhibitory matrices such as feces and urine |
The matrix, the lowest concentration you need to quantify (LLOQ), and the number of samples decide which platform fits. We can compare both in your matrix during method development, before you lock the assay.
Validation
How do we develop and validate shedding assays?
A shedding result is only as reliable as the extraction and the controls behind it. Drawing on more than 20 years of experience in nucleic acid extraction and PCR assay validation, we build each assay around four questions:
Does the spike-in behave like the shed product?
Spike-in controls mimic the drug product as closely as possible: inside a viral capsid, formulated in lipid nanoparticles or as free nucleic acid. If the product is shed as intact particles, the extraction must recover nucleic acid from those particles, and the spike-in must prove that it does.
How much target is recovered from each matrix?
Every extraction loses some target. We measure extraction efficiency and recovery in each matrix, so you know how much analyte is lost and whether that loss is consistent from sample to sample. Where storage and shipping could degrade the analyte, mock samples can be spiked at the point of collection to measure those losses, as the FDA shedding guidance recommends.
Is the PCR inhibited?
RNA spikes check for interference in the reverse transcription step and DNA spikes for interference in the PCR. Inhibition is minimized, characterized and accounted for in the final method, for example through a defined sample dilution.
How low can the assay go?
We establish the limit of blank (LOB), limit of detection (LOD) and lower limit of quantification (LLOQ) in the study matrix, together with specificity against unspiked matrix and related sequences, precision, accuracy and sample stability.
The depth of validation follows the context of use: a fit-for-purpose qualification for early and exploratory studies, and a full validation against a predefined protocol when the data support regulatory decisions. Our PCR assay validation guide explains each step.
GLP, GCLP and the regulatory framework for shedding studies
Regulatory Compliance and Quality Assurance
Shedding data end up in regulatory submissions, so they must hold up at inspection years later. Our Gothenburg laboratory is accredited for Good Laboratory Practice (GLP) by SWEDAC, the Swedish Board for Accreditation and Conformity Assessment, for qPCR, dPCR and molecular biology, and holds ISO/IEC 17025 accreditation. Clinical shedding samples are analyzed under Good Clinical Laboratory Practice (GCLP), which combines GLP principles with Good Clinical Practice for samples from clinical trials. Studies that do not need a regulated framework run as non-GLP studies with the same assay design and controls.
Under GLP, sample management, the work environment, instrument maintenance, temperature monitoring, staff training and IT security sit within one quality system, and every sample-handling step is time-stamped to give a complete audit trail.
Study designs follow the FDA guidance Design and Analysis of Shedding Studies for Virus or Bacteria-Based Gene Therapy and Oncolytic Products (2015) and the ICH Considerations document General Principles to Address Virus and Vector Shedding (2009). Because ICH M10 was written for chromatographic and ligand-binding assays rather than PCR, our validations follow the MIQE guidelines our team helped write (Bustin et al., Clinical Chemistry, 2009; updated as MIQE 2.0 in 2025) and the 2024 AAPS recommendations for qPCR and dPCR assays in cell and gene therapy (Hays et al., The AAPS Journal, 2024).
Safety evaluation
A complete safety package for gene therapies
Shedding is one part of the safety evaluation a gene therapy program needs. You can run the related studies with us as well:
| Study | What it shows |
|---|---|
| Shedding | What leaves the body, how much and for how long |
| Biodistribution | Vector genomes in target and non-target tissues and biofluids, by qPCR and dPCR |
| Vector copy number | Vector copies per cell or per genome |
| Transgene expression | Whether, and how much, the transgene is expressed, by RT-qPCR and RT-dPCR |
| Vector integrity and integration | Whether vector genomes are intact and where they have integrated, by sequencing |
| Single-cell and spatial biodistribution (extra) | Which cell types take up the vector and express the transgene, and where in the tissue |
| Persistence in specific cell types (extra) | Single-cell sequencing of blood cells shows which cell types still carry the therapy |
Contact us to discuss combining these studies into one study plan.
Workflow
How a shedding project runs
Step 1
Scoping call
We discuss your product and construct, species, sample matrices, sampling schedule, sample numbers and the quality framework the study needs.
Step 2
Assay design
We design primers and probes against non-natural sequences in your construct and check them against host and wild-type sequences.
Step 3
Method development
We set up extraction and PCR for each matrix, choose the spike-in strategy and test recovery and inhibition, on qPCR, dPCR or both.
Step 4
Qualification or validation
We qualify or validate the method to the level the context of use requires, under GLP or GCLP when the study needs it.
Step 5
Sample analysis
Study samples are analyzed in runs with quality controls, and results are reported per volume or mass of the original sample, for example copies per mL of urine or per milligram of stool.
Step 6
Reporting
You receive the qualification or validation report and the sample analysis results, ready for your study report or regulatory submission.
Wondering if this service can
help answer your biological question?
Request a quote today and find out how our expertise can support your research.
What our clients say
“Every step of the process has been perfect, starting from the initial informative meeting, where I received useful suggestions, to the experimental phase, which was carried out very quickly. Additionally, communication has been prompt and highly effective.”
"The service of Single Cell Discoveries guarantees a smooth process between customer and company. In case of problems or questions, the scientists reacted competently and immediately, so that answers could be found quickly and flexibly."
Comparison
Shedding vs. Biodistribution Studies: What's the Difference?
Shedding and biodistribution studies provide complementary information about the behavior and safety of gene therapy vectors. While biodistribution studies assess where a vector travels and persists within the body, shedding studies investigate whether vector material is released through bodily fluids or excreta. Understanding these differences helps researchers select appropriate sampling strategies, analytical methods, and study designs.
| Study aspect | Shedding studies | Biodistribution studies |
|---|---|---|
| Primary objective | Evaluate the release of vector material from the treated subject | Determine the distribution and persistence of vector material in the body |
| Key research question | Is vector material released, and could it potentially expose others? | Which tissues and organs contain vector material, and for how long? |
| Typical sample types | Urine, saliva, feces, nasal secretions, and other bodily fluids | Blood, target organs, non-target tissues, and reproductive organs |
| Analytical techniques | qPCR and dPCR for vector nucleic acid detection and quantification; infectivity assays when relevant | qPCR and dPCR for vector nucleic acid quantification; complementary methods where appropriate |
| Data generated | Presence, quantity, duration, and clearance patterns of shed vector material | Tissue distribution, vector abundance, persistence, and clearance profiles |
| Research applications | Understanding vector release, informing biosafety assessments, and evaluating potential environmental exposure | Investigating tissue targeting, off-target distribution, vector persistence, and delivery efficiency |
| Regulatory relevance | Supports shedding and environmental risk assessments, where applicable | Supports nonclinical biodistribution assessments under ICH S12 |
| Study design considerations | Sampling matrices, collection time points, assay sensitivity, and interpretation of low-level detection | Tissue selection, sampling time points, assay sensitivity, and interpretation of tissue-specific results |
Recent publications on shedding studies
bioRxiv
A Double-Negative Prostate Cancer Subtype is Vulnerable to SWI/SNF-Targeting Degrader Molecules
bioRxiv
SP140 limits type I interferon-driven pathology, preserving T cell motility and promoting resistance in tuberculosis
Nature Communications
Targeted CRISPR-Cas9 screening identifies core transcription factors controlling murine haemato-endothelial fate commitment
npj Precision Oncology
A single-cell atlas reveals the tumorigenesis and microenvironment status of primary tracheobronchial tumors
Nature Cardiovascular Research
Oxidative phosphorylation is required for cardiomyocyte re-differentiation and long-term fish heart regeneration
Research Square
GPR124/WNT signaling regulates hyaloid blood vessel regression and endothelial-mesenchymal transition
Case studies
Pioneering 10x Flex on OCT-Embedded Patient Brain Tissue
10x Genomics opened the gates for single-cell sequencing on non-fresh, non-thawed tissue with their Chromium Single Cell Gene Expression Flex (10x Flex) kit. Now, we have been successful in performing…
Immune Profiling of atherosclerosis reveals new therapeutic potential
A team of scientists uses 10x Genomics Single Cell Immune Profiling to characterize T cells in the atherosclerotic plaque. Their results redefine atherosclerosis as an autoimmune disease.
Mechanism of disease: a new hypothesis for atherosclerosis
To elucidate atherosclerosis’ mechanism of disease, Sheffield University researchers analyzed the transcriptomes of single endothelial cells.
Recent blogs on shedding studies
Linearity, Co-linearity, Robustness, Ruggedness and Stability in qPCR and dPCR Validation
Part 4 of the PCR Assay Validation Guide — The Final Chapter This post concludes SCD’s PCR Assay Validation Guide. In Part 1 we introduced the principles of assay development,…
Gene set enrichment analysis: From Genes to Biological Processes
Gene set enrichment analysis (GSEA) helps translate gene-level expression changes into broader biological processes. It starts with a ranked list of all tested genes, usually based on a signed statistic…
Sensitivity and Specificity in Regulated Bioanalytical Assay Validation
Part 3 of the PCR Assay Validation Guide This post continues the PCR Assay Validation Guide. In Part 1 we introduced the principles of development, qualification and validation and the…
Frequently asked questions about shedding studies
Biodistribution describes how a product spreads within the body from the site of administration, into tissues and biofluids. Shedding describes how it is released from the body: in excreta, in secreta or through the skin. Both are usually measured by qPCR or dPCR, often within the same development program. See Biodistribution.
No. qPCR and dPCR detect viral or vector nucleic acid and cannot distinguish intact, infectious particles from degraded fragments. Infectivity is tested in a cell-based assay, usually on the PCR-positive samples, so PCR serves as the sensitive first screen.
dPCR tolerates the PCR inhibitors in feces and urine better and quantifies without a standard curve. qPCR is the established, cost-effective choice with a wide dynamic range. The matrix and the required LLOQ decide, and we can compare both technologies in your matrix during method development.
Feces, urine, saliva, sputum, nasopharyngeal fluids, tears, skin lesions such as pustules, sores or wounds, semen, vaginal secretions, swabs and breast milk. Blood is analyzed as part of pharmacokinetics. Uncommon matrices start with a feasibility test of recovery and inhibition.
The FDA guidance "Design and Analysis of Shedding Studies for Virus or Bacteria-Based Gene Therapy and Oncolytic Products" (2015) and the ICH Considerations document "General Principles to Address Virus and Vector Shedding" (2009). Preclinical studies run under GLP, clinical studies under GCLP.
Not always. The FDA guidance (2015) does not expect shedding assays to be validated, but they must be qualified to meet minimum performance requirements (sensitivity, specificity, reproducibility) and suit their purpose. Studies run under GLP, or data that support pivotal regulatory decisions, may call for a full validation against a predefined protocol. Part 1 of our PCR assay validation guide explains the difference between development, qualification and validation.
The FDA guidance (2015) recommends starting right after dosing, sampling often in the first weeks, for example on days 1, 3, 7 and 10 and then weekly, and continuing until three consecutive samples are at or below the assay’s limit of detection, or until levels plateau over three consecutive time points. Replication-competent products usually need longer monitoring than replication-incompetent vectors such as AAV.
For replication-incompetent vectors such as AAV and E1-deleted adenovirus, the FDA guidance considers qPCR adequate as the primary shedding assay. For replication-competent and oncolytic products, PCR-positive samples should be followed up with an infectivity assay, such as a TCID50 or plaque assay. We run the qPCR and dPCR analysis; keep separate sample aliquots for infectivity testing.
The FDA guidance asks shedding reports to address whether PCR-positive samples contain full-length genomes or mainly degraded fragments. This can be investigated using an infectivity assay, which is not part of SCD service offerings.
Shedding and biodistribution studies provide complementary safety information, but their requirements depend on the therapeutic product, vector characteristics, route of administration, and development stage. Biodistribution studies assess where a gene therapy vector travels within the body, while shedding studies evaluate its release through excreta or secretions. Regulatory guidance, including ICH S12 and FDA recommendations, can help determine the appropriate study design.
Request a quote
Plan your shedding study with our scientists
Tell us your product, matrices, species and study phase. Our scientists will propose an assay strategy and the level of qualification or validation your study needs.